大香蕉毛片视频免费下载_91香蕉小视频在线观看_WWW香蕉视频APP_香蕉视频黄软件-亚洲欧美日韩国产成人在线_日韩中文字幕无码一区二区_

產(chǎn)品中心

小鼠神經(jīng)介素B(NMB)酶聯(lián)免疫吸附檢測(cè)試劑盒
一鍵復(fù)制產(chǎn)品信息
ELK1630
規(guī)格: 價(jià)格:
48T ¥1960.00
96T ¥2800.00

Overview

Product name: Mouse NMB(Neuromedin B) ELISA Kit
Reactivity: Mouse
Alternative Names: NM-B
Assay Type: Competitive Inhibition
Sensitivity: 4.87 pg/mL
Standard: 1000 pg/mL
Detection Range: 15.63-1000 pg/mL
Sample type: Serum, plasma and other biological fluids.
Assay length: 2h
Research Area: Signal transduction;Endocrinology;Neuro science;Gastroenterology;Hormone metabolism;
Uniprot ID: Q9CR53
Test principle: This assay employs the competitive inhibition enzyme immunoassay technique. The microtiter plate provided in this kit has been pre-coated with Mouse NMB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Mouse NMB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Mouse NMB in the samples is then determined by comparing the OD of the samples to the standard curve.

標(biāo)準(zhǔn)曲線

Concentration (pg/mL) OD Corrected OD
1000.00 0.219
500.00 0.427
250.00 0.715
125.00 0.959
62.50 1.275
31.25 1.579
15.63 1.889
0.00 2.265

精密度

Intra-assay Precision (Precision within an assay):CV%<8%

Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision.

Inter-assay Precision (Precision between assays):CV%<10%

Three samples of known concentration were tested in forty separate assays to assess inter-assay precision.

回收率

Matrices listed below were spiked with certain level of recombinant NMB and the recovery rates were calculated by comparing the measured value to the expected amount of NMB in samples.
Matrix Recovery range Average
serum(n=5) 90-105% 97%
EDTA plasma(n=5) 84-97% 90%
Heparin plasma(n=5) 81-95% 88%

線性

The linearity of the kit was assayed by testing samples spiked with appropriate concentration of NMB and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Matrix 1:2 1:4 1:8 1:16
serum(n=5) 87-101% 87-96% 82-93% 89-97%
EDTA plasma(n=5) 85-93% 98-105% 87-98% 95-102%
Heparin plasma(n=5) 85-94% 79-96% 92-105% 91-99%
關(guān)閉

在線咨詢

Online consultation

  • 在線咨詢
  • 技術(shù)支持

關(guān)注微信公眾號(hào)

微信掃一掃立即咨詢

微信掃一掃立即咨詢

關(guān)閉